Por favor, use este identificador para citar o enlazar este ítem:
http://repositorio.ikiam.edu.ec/jspui/handle/RD_IKIAM/159
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Starr, B.J. | - |
dc.contributor.author | Tarabara, Volodymyr | - |
dc.contributor.author | Herrera Robledo, Miguel | - |
dc.contributor.author | Zhou, M. | - |
dc.contributor.author | Roualdes, S. | - |
dc.contributor.author | Ayral, André | - |
dc.date.accessioned | 2019-06-05T20:21:41Z | - |
dc.date.available | 2019-06-05T20:21:41Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Starr, B. J., Tarabara, V. V., Zhou, M., Herrera Robledo, M., & Ayral, A. (2016). Coating porous membranes with a photocatalyst: Comparison of LbL self-assembly and plasma-enhanced CVD techniques. Journal of Membrane Science, 514, 340–349. doi.org/10.1016/j.memsci.2016.04.050 | es |
dc.identifier.other | DOI: 10.1016/j.memsci.2016.08.063 | - |
dc.identifier.uri | http://dspace.ikiam.edu.ec:8080/jspui/handle/RD_IKIAM/159 | - |
dc.identifier.uri | https://doi.org/10.1016/j.memsci.2016.04.050 | - |
dc.description.abstract | In the published version of the manuscript, some of the values in Table 2 did not match the headings: 1) In the Table 2 heading, units of the 2nd order reaction rate constant, [Formula presented], were indicated to be m/s. However, the values of [Formula presented] provided in the Table were in units of L/(s m²).2) In the Table 2 heading, units of the reactive flux, [Formula presented], were indicated to be m/s. However, the values of [Formula presented] provided in the Table were in units of L/min (i.e. were not normalized by the membrane surface area).3) Values of [Formula presented] for the 5 layer LBL membrane need to be corrected:– Test #1: (8.90±2.10)·10⁻⁴ L/(s m²) should be changed to (9.65±1.76)·10⁻⁴ L/(s m²). After units conversions, the correct value is (11.61±2.12) 10⁻⁶ m/s.– Test #2: (8.66±0.27)·10⁻⁴ L/(s m²) should be changed to (8.65±0.28)·10⁻⁴ L/(s m²). After units conversions, the correct value is (10.41±0.34) 10⁻⁶ m/s.– Test #3: (6.74±0.27)·10⁻⁴ L/(s m²) should be changed to (6.79±0.37)·10⁻⁴ L/(s m²). After units conversions, the correct value is (8.17±0.45) 10⁻⁶ m/s.The revised Table 2 with correct values of [Formula presented] and [Formula presented] in units of m/s is attached below. In addition, the last sentence on page 345 of the published manuscript contained a typo, wherein [Formula presented] was assigned the value of 8.0·10⁻⁶±1.5·10⁻⁶ m/s instead of the correct value of 7.9·10⁻⁶±0.8·10⁻⁶ m/s. (Note that Table 2 in the published manuscript contains the correct value). Thus, the sentence should read as follows: “The normalized 1st order reaction rate constants are (7.9±0.8)·10⁻⁶ m/s and (6.0±0.0)·10⁻⁶ m/s for P25 and PECVD-generated catalysts, respectively.” The authors would like to apologize for these errors. http://dx.doi.org/10.1016/j.memsci.2016.04.050. | es |
dc.language.iso | en | es |
dc.publisher | Elsevier | es |
dc.relation.ispartofseries | PRODUCCIÓN CIENTÍFICA-ARTÍCULOS;A-IKIAM-000097 | - |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América | * |
dc.rights | openAccess | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Membranes | es |
dc.subject | Photocatalyst | es |
dc.subject | LBL | es |
dc.subject | CVD techniques | es |
dc.title | “Coating porous membranes with a photocatalyst: Comparison of LbL self-assembly and plasma-enhanced CVD techniques” | es |
dc.type | Article | es |
Aparece en las colecciones: | ARTÍCULOS CIENTÍFICOS |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
A-IKIAM-000097.pdf | Coating porous membranes with a photocatalyst: Comparison of LbL self-assembly and plasma-enhanced CVD techniques | 2,53 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons