Repositorio Dspace

Evaluation of Data Acquisition System for PES Membranes Permeability Analysis in Water Treatment

Mostrar el registro sencillo del ítem

dc.contributor.author Basantes Montero, David Trajano
dc.contributor.author Rosero Ortíz, Bryan Rafael
dc.contributor.author Barzallo Núñez, Daniel Isaías
dc.contributor.author Quishpe Quishpe, Luis Miguel
dc.contributor.author Herrera Robledo, Miguel
dc.contributor.author Maya Izurieta, Néstor Xavier
dc.date.accessioned 2022-10-14T15:37:05Z
dc.date.available 2022-10-14T15:37:05Z
dc.date.issued 2022
dc.identifier.citation Basantes Montero, D.T., Rosero Ortiz, B.R., Barzallo Núñez, D.I., Quishpe Quishpe, L.M., Maya Izurieta, N.X., Herrera Robledo, M. (2023). Evaluation of Data Acquisition System for PES Membranes Permeability Analysis in Water Treatment. In: Zambrano Vizuete, M., Botto-Tobar, M., Diaz Cadena, A., Zambrano Vizuete, A. (eds) I+D for Smart Cities and Industry. RITAM 2021. Lecture Notes in Networks and Systems, vol 512. Springer, Cham. https://doi.org/10.1007/978-3-031-11295-9_8 es
dc.identifier.issn https://doi.org/10.1007/978-3-031-11295-9_8
dc.identifier.uri http://repositorio.ikiam.edu.ec/jspui/handle/RD_IKIAM/606
dc.description.abstract Wastewater treatment has become a momentous field today. Membrane ultrafiltration processes are booming due to their versatility of use. However, there are limited studies related to the technology of automatic data acquisition systems (DAQ) for the analysis of pore fouling based on the permeability of the membranes. Thus, the objective of this research was to evaluate a DAQ system through its implementation in permeability tests of polyethersulfone (PES) membranes. For this, through the ANOVA-non-replicable method, the repeatability and reproducibility (r & R) of the data obtained from manual measurements (MA) and DAQ system measurements were analyzed. The tests were carried out through scenarios of filtering distilled water (W) and filtering water contaminated with standard foulant (BSA). The results show a percentage of the r & R relationship between 10% and 30%, concluding that the measurement system through the DAQ system is acceptable according to its use. es
dc.language.iso en es
dc.publisher Scopus es
dc.relation.ispartofseries PRODUCCIÓN CIENTÍFICA-ARTÍCULO CIENTÍFICO;CL-IKIAM-000018
dc.subject DAQ es
dc.subject ANOVA es
dc.subject Repetibilidad es
dc.subject Reproducibilidad es
dc.subject Ultrafiltración es
dc.subject Membranas PES es
dc.title Evaluation of Data Acquisition System for PES Membranes Permeability Analysis in Water Treatment es
dc.type Book chapter es


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta