Repositorio Dspace

“Coating porous membranes with a photocatalyst: Comparison of LbL self-assembly and plasma-enhanced CVD techniques”

Mostrar el registro sencillo del ítem

dc.contributor.author Starr, B.J.
dc.contributor.author Tarabara, Volodymyr
dc.contributor.author Herrera Robledo, Miguel
dc.contributor.author Zhou, M.
dc.contributor.author Roualdes, S.
dc.contributor.author Ayral, André
dc.date.accessioned 2019-06-05T20:21:41Z
dc.date.available 2019-06-05T20:21:41Z
dc.date.issued 2016
dc.identifier.citation Starr, B. J., Tarabara, V. V., Zhou, M., Herrera Robledo, M., & Ayral, A. (2016). Coating porous membranes with a photocatalyst: Comparison of LbL self-assembly and plasma-enhanced CVD techniques. Journal of Membrane Science, 514, 340–349. doi.org/10.1016/j.memsci.2016.04.050 es
dc.identifier.other DOI: 10.1016/j.memsci.2016.08.063
dc.identifier.uri http://dspace.ikiam.edu.ec:8080/jspui/handle/RD_IKIAM/159
dc.identifier.uri https://doi.org/10.1016/j.memsci.2016.04.050
dc.description.abstract In the published version of the manuscript, some of the values in Table 2 did not match the headings: 1) In the Table 2 heading, units of the 2nd order reaction rate constant, [Formula presented], were indicated to be m/s. However, the values of [Formula presented] provided in the Table were in units of L/(s m²).2) In the Table 2 heading, units of the reactive flux, [Formula presented], were indicated to be m/s. However, the values of [Formula presented] provided in the Table were in units of L/min (i.e. were not normalized by the membrane surface area).3) Values of [Formula presented] for the 5 layer LBL membrane need to be corrected:– Test #1: (8.90±2.10)·10⁻⁴ L/(s m²) should be changed to (9.65±1.76)·10⁻⁴ L/(s m²). After units conversions, the correct value is (11.61±2.12) 10⁻⁶ m/s.– Test #2: (8.66±0.27)·10⁻⁴ L/(s m²) should be changed to (8.65±0.28)·10⁻⁴ L/(s m²). After units conversions, the correct value is (10.41±0.34) 10⁻⁶ m/s.– Test #3: (6.74±0.27)·10⁻⁴ L/(s m²) should be changed to (6.79±0.37)·10⁻⁴ L/(s m²). After units conversions, the correct value is (8.17±0.45) 10⁻⁶ m/s.The revised Table 2 with correct values of [Formula presented] and [Formula presented] in units of m/s is attached below. In addition, the last sentence on page 345 of the published manuscript contained a typo, wherein [Formula presented] was assigned the value of 8.0·10⁻⁶±1.5·10⁻⁶ m/s instead of the correct value of 7.9·10⁻⁶±0.8·10⁻⁶ m/s. (Note that Table 2 in the published manuscript contains the correct value). Thus, the sentence should read as follows: “The normalized 1st order reaction rate constants are (7.9±0.8)·10⁻⁶ m/s and (6.0±0.0)·10⁻⁶ m/s for P25 and PECVD-generated catalysts, respectively.” The authors would like to apologize for these errors. http://dx.doi.org/10.1016/j.memsci.2016.04.050. es
dc.language.iso en es
dc.publisher Elsevier es
dc.relation.ispartofseries PRODUCCIÓN CIENTÍFICA-ARTÍCULOS;A-IKIAM-000097
dc.rights Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América *
dc.rights openAccess es_ES
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Membranes es
dc.subject Photocatalyst es
dc.subject LBL es
dc.subject CVD techniques es
dc.title “Coating porous membranes with a photocatalyst: Comparison of LbL self-assembly and plasma-enhanced CVD techniques” es
dc.type Article es


Ficheros en el ítem

El ítem tiene asociados los siguientes ficheros de licencia:

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta