Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ikiam.edu.ec/jspui/handle/RD_IKIAM/102
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGallardo, Andrés-
dc.contributor.authorPalme, Massimo-
dc.contributor.authorLobato Cordero, Andrea-
dc.contributor.authorBeltrán, R. David-
dc.contributor.authorGaona, Gabriel-
dc.date.accessioned2019-05-17T20:42:38Z-
dc.date.available2019-05-17T20:42:38Z-
dc.date.issued2016-
dc.identifier.citationGallardo, A., Palme, M., Lobato-Cordero, A., Beltrán, R., & Gaona, G. (2016). Evaluating Thermal Comfort in a Naturally Conditioned Office in a Temperate Climate Zone. Buildings, 6(3), 27. doi:10.3390/buildings6030027es
dc.identifier.otherhttps://doi.org/10.3390/buildings6030027-
dc.identifier.urihttp://repositorio.ikiam.edu.ec/jspui/handle/RD_IKIAM/102-
dc.identifier.urihttps://doi.org/10.3390/buildings6030027-
dc.description.abstractThis study aims to determine the optimal approach for evaluating thermal comfort in an office that uses natural ventilation as the main conditioning strategy; the office is located in Quito-Ecuador. The performance of the adaptive model included in CEN Standard EN15251 and the traditional PMV model are compared with reports of thermal environment satisfaction surveys presented simultaneously to all occupants of the office to determine which of the two comfort models is most suitable to evaluate the thermal environment. The results indicate that office occupants have developed some degree of adaptation to the climatic conditions of the city where the office is located (which only demands heating operation), and tend to accept and even prefer lower operative temperatures than those considered optimum by applying the PMV model. This is an indication that occupants of naturally conditioned buildings are usually able to match their comfort temperature to their normal environment. Therefore, the application of the adaptive model included in CEN Standard EN15251 seems like the optimal approach for evaluating thermal comfort in naturally conditioned buildings, because it takes into consideration the adaptive principle that indicates that if a change occurs such as to produce discomfort, people tend to react in ways which restore their comfort.es
dc.description.sponsorshipMolecular Diversity Preservation Internationales
dc.language.isoenes
dc.publisherStamats Buildings Media, Inc.es
dc.relation.ispartofseriesPRODUCCION CIENTÍFICA-ARTÍCULOS;A-IKIAM-000044-
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Estados Unidos de América*
dc.rightsopenAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectThermal comfortes
dc.subjectAdaptive comfort modeles
dc.subjectPMV modeles
dc.subjectNaturally conditioned buildingses
dc.subjectComfort temperaturees
dc.titleEvaluating Thermal Comfort in a Naturally Conditioned Office in a Temperate Climate Zonees
dc.typeArticlees
Aparece en las colecciones: ARTÍCULOS CIENTÍFICOS

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
A-IKIAM-000044.pdfEvaluating Thermal Comfort in a Naturally Conditioned Office in a Temperate Climate Zone3,42 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons